Skip to main content

Andrew Spence

Andrew Spence

Air Receiver/Compressor Moisture Removal Check List

Air Receiver/Compressor Moisture Removal Check List

The Compressor Air Receiver should be stood on level and stable ground

  1. Make sure the air compressor Motor Switch is in the “OFF” position and the plug is removed from the socket.
  • Check the electrical plug socket and cable for defects
  • Remove any moisture in the air compressor tank:
  • NEVER attempt to open the drain valve when more than 10 PSI of air pressure is in the air tank, check the gage!
  • Remove excessive pressure by pulling on the safety relief valve ring.
  • Open the air tank drain valve in the bottom of the air tank (circled above).
  • Close tightly when drained
  • Make sure all safety valves are working correctly.
  • Make sure all guards and covers are in place and securely mounted.
  • Make sure that the pressure line and pressure tools are free of defects

Do not use if the compressor/air receiver, electrical supply, pressure lines or associated equipment appear defective or damaged.